Bacharach Model 100 Specifications Page 54

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 53
Instruction 0024-9395
48
Fyrite Pro
5.8 Water Trap / Filter Maintenance
The Water Trap / Filter Assembly removes water con den sate from the gas
sam ple, and also prevents soot from con tam i nat ing the internal com po-
nents of the analyzer.
Drain the water condensate after every test.
Procedure:
1. Disassemble the trap (see Figure 5-3).
2. Pour out all water condensate; then reassemble the trap.
Replace the Filter Element when dirty.
Material Required: • Filter Element, P/N 0007-1644
• Small Flat Blade Screwdriver
Procedure:
1. Disassemble the trap (see Figure 5-3).
2. Remove and discard old filter.
3. Install new filter and reassemble trap.
Figure 5-3. Water Trap / Filter Assembly
Pull apart using a slight
twisting motion
WATER TRAP
CHAMBER
FILTER
CHAMBER
FILTER ELEMENT
Pry apart filter chamber using
a small flat-blade screwdriver
inserted into notch
“A” “B”
When reassembling
the trap, make sure
that surfaces “A” and
“B” are in contact.