Fyrite® ProCombustion Gas AnalyzerInstruction 0024-9395Operation & MaintenanceRev. 12 – October 2010Product Leadership • Training • Service • Reli
Instruction 0024-93954Fyrite ProMemory (Model 105/110/120/125) ... Up to 10 sets of readings can be saved in memory. When memory is
Instruction 0024-93955Fyrite Pro3.0 SETTING UP THE ANALYZER3.1 Preliminary StepsBefore using the analyzer . . .• Check batteries (Section 3.2)• Conne
Instruction 0024-93956Fyrite Pro3.3 Connecting the Probe Hose and ThermocoupleThe analyzer’s model number determines which hose and thermocouple conn
Instruction 0024-93957Fyrite ProFigure 3-2A. Connecting the 0019-7110 Probe (Model 100)GAS INLETSAMPLE-GASHOSEWATER TRAP /FILTER ASSEMBLYAC ADAPTERJAC
Instruction 0024-93958Fyrite ProFigure 3-2B. Connecting the 0024-3004 Probe (Model 105)DIFFERENTIALPRESSURE HOSE(Optional)WATER TRAP / FILTERASSEMBLYP
Instruction 0024-93959Fyrite ProFigure 3-2C. Connecting the 0019-7111 Probe (Model 110/120)T-STACKGASINLETSAMPLE-GASHOSETHERMOCOUPLECONNECTOR(T-STACK)
Instruction 0024-939510Fyrite ProFigure 3-2D. Connecting the 0024-3004 Probe (Model 125)T-STACKT-AIRROOM AIR /PRIMARY AIRTHERMOCOUPLECONNECTOR(T-AIR)D
Instruction 0024-939511Fyrite Pro3.4 Front Panel Push ButtonsNote that a push button may perform several functions, depending on the analyzer’s model
Instruction 0024-939512Fyrite Pro3.5 Setup ModeThe analyzer is preset at the factory for the parameters shown below, but can be changed as described
Instruction 0024-939513Fyrite Pro3.5.3 CO Channel SetupThe CO Channel Setup Screen is labeled “CO.” 1. Enter the Setup Mode per Section 3.5.1. If nec
WARRANTYBacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in mater ial and manufac ture and will c
Instruction 0024-939514Fyrite Pro3.5.5 Time SetupThere are two Time Setup Screens, one for hours and the other for min-utes. Two bars appear above th
Instruction 0024-939515Fyrite Pro3.5.7 Year SetupThe Year Setup Screen is labeled “YEAr”.1. Enter the Setup Mode per Section 3.5.1. If necessary, rep
Instruction 0024-939516Fyrite ProNotes:
Instruction 0024-939517Fyrite Pro4.0 OPERATION4.1 Performing CO and Draft Testing4.1.1 Analyzer Turn On and Warm Up1. Connect the probe and make su
Instruction 0024-939518Fyrite Pro4.1.2 Measuring CO (Model 100/105/120/125)1. Turn ON the analyzer and allow it to warm-up per Section 4.1.1.Importan
Instruction 0024-939519Fyrite Pro4.2 Performing a Combustion Test using the Model 110/120/1254.2.1 Analyzer Turn On and Warm UpImportant: The probe
Instruction 0024-939520Fyrite ProAtmospheric Burner or Gravity Vented Forced Air Hot Water Tank4.2.3 Sampling PointForced Air Furnace – When testing a
Instruction 0024-939521Fyrite Pro90% Eff. Condensing Furnace/BoilerAtmospheric or Gravity Vented Boiler 80% Eff. Fan Assist or Power Vented Furnace/B
Instruction 0024-939522Fyrite Pro4.2.4 Performing a Com bus tion Efficiency Test1. After turning ON the analyzer and selecting the appropriate fuel,
Instruction 0024-939523Fyrite Pro4.3 Operating Tips• When an analyzer is brought in from a cold vehicle, let it warm up slowly to minimize condensatio
Fyrite ProInstruction 0024-9395iContentsOrdering Information ... iii1.0 INTRODUCTION ...
Instruction 0024-939524Fyrite Pro4.4 Using the BacklightThe LCD can be read in dimly-lit areas by pressing the LIGHT button. The backlight automatica
Instruction 0024-939525Fyrite Pro2. Press the ▼ button once to display the Save Screen. The number shown in this screen represents the memory location
Instruction 0024-939526Fyrite Pro4.8 Printing Test DataTip: To avoid printing errors, it is important to select the correct protocol per Section 3.5
Instruction 0024-939527Fyrite ProFigure 4-1. Printer Alignment & Sample Printout60°max.45 cm(18 in.)max.ENTERHOLDI/OLIGHT BACHARACH, INC. FY
Instruction 0024-939528Fyrite Pro4.9 Clearing Saved Test Data (Model 105/110/120/125)Clear all saved test data as follows:Note: If no test data has b
Instruction 0024-939529Fyrite ProFigure 4-2A. Model 100 Run Mode Screen9COPPMCO4.11 Resetting the MicroprocessorIf the analyzer ‘locks up’ and canno
Instruction 0024-939530Fyrite ProFigure 4-2C. Model 110 Run Mode ScreensFuel Select:F1 = Natural GasF2 = Oil #2F3 = LPGF4 = KeroseneO2Ambient /Combus
Instruction 0024-939531Fyrite ProFigure 4-2D. Model 120 Run Mode ScreensFuel Select:F1 = Natural GasF2 = Oil #2F3 = LPGF4 = KeroseneCO & O2CO Air
Instruction 0024-939532Fyrite ProFigure 4-2E. Model 125 Run Mode ScreensFuel Select:F1 = Natural GasF2 = Oil #2F3 = LPGF4 = KeroseneCO & O2CO Air
Instruction 0024-939533Fyrite Pro4.13 Screen Descriptions4.13.1 Warm-Up Screens As soon as the analyzer is turned ON, a se
Fyrite ProInstruction 0024-9395ii4.7 Opening and Viewing Saved Test Data ... 254.8 Printing Test Data...
Instruction 0024-939534Fyrite Pro4.13.3 CO & Draft Screen (Model 105/125)The CO reading is a measurement of how much carbon monoxide in ppm is pr
Instruction 0024-939535Fyrite Pro4.13.5 Fuel Screen (Model 110/120/125) The Fuel Screen is displayed after warm-up, and is where an operator chooses w
Instruction 0024-939536Fyrite ProThe CO reading is a measurement of how much carbon monoxide in ppm is present in the flue-gas stream. Note, however,
Instruction 0024-939537Fyrite Pro4.13.9 Temperature Differential Screen (Model 125)The Temperature Differential reading is the measured difference be
Instruction 0024-939538Fyrite Pro4.13.11 Ambient Air Temperature Screen (Model 110/120/125) The AMBIENT reading is the combustion-air temperature in
Instruction 0024-939539Fyrite Pro4.13.13 Sensor Error Screen (Model 100/105/110/120/125) An O2 sensor error is displayed if the analy
Instruction 0024-939540Fyrite ProNotes:
Instruction 0024-939541Fyrite Pro5.0 CALIBRATION & MAINTENANCEImportant: Fresh batteries should be installed, and the unit allowed to sta bi lize
Instruction 0024-939542Fyrite Pro5.2 Ambient Temperature Calibration (Model 110/120/125)Material Required: Calibrated ThermometerProcedure:1. Enter
Instruction 0024-939543Fyrite Pro3. Set the simulator to 32.0 °F (0 °C); then use the ▲ and ▼ buttons to set the dis played value to match the simula
Fyrite ProInstruction 0024-9395iiiOrdering InformationFyrite Pro Confi gurationsModel 100 100 Printer Kit105 110 120 125 125 Printer Kit125 Printer/Oil
Instruction 0024-939544Fyrite Pro6. Press ENTER to store these calibration values and move to the next cal i bra tion screen, or hold down ENTER for 2
Instruction 0024-939545Fyrite Pro9. Press ENTER to store the new calibration values and move to the next cal i bra tion screen, or hold down ENTER for
Instruction 0024-939546Fyrite Pro6. Connect the tubing of the Calibration Kit to the GAS inlet of the an- a lyz er. Note that the gas fitting (Item 6
Instruction 0024-939547Fyrite Pro5.7 Draft Calibration (Model 105/125)Material Required: • Bellows • Micromanometer Range: ±8 in. H2O column (±2
Instruction 0024-939548Fyrite Pro5.8 Water Trap / Filter MaintenanceThe Water Trap / Filter Assembly removes water con den sate from the gas sam ple,
Instruction 0024-939549Fyrite Pro5.9 O2 Sensor Replacement (Model 110/120/125)Be sure to perform all of the checks listed in Sec tion 4.13.13 to ensur
Instruction 0024-939550Fyrite Pro5.10 CO Sensor Replacement (Model 100/105/120/125)Be sure to perform all of the checks listed in Sec tion 4.13.13 to
Instruction 0024-939551Fyrite Pro5.11 Pump Assembly ReplacementMaterial Required: • Pump, P/N 0024-3048 • #1 Phillips ScrewdriverProcedure:1. Disa
Instruction 0024-939552Fyrite ProFigure 5-4. Case Components & Plumbing SchematicCO SENSORGASKET(Model 125E only)OXYGEN SENSOR& SOCKETPRESSUR
Instruction 0024-939553Fyrite ProFigure 5-5. PCB ComponentsCOSENSOR(Model 125E only)ToBATTERYToOXYGENSENSORToPUMPPRESSURESENSOR(RED WIRE)(RED WIRE)(RE
Fyrite ProInstruction 0024-9395ivNotes:
Instruction 0024-939554Fyrite ProNotes:
Instruction 0024-939555Fyrite Pro6.0 PARTS & SERVICE6.1 Replacement PartsDescription Part No.Carbon Monoxide Sensor ...
Instruction 0024-939556Fyrite Pro6.2.2 Optional AccessoriesAC Adapter (Battery Eliminator) ...0024-12
Instruction 0024-939557Fyrite ProUnited States621 Hunt Valley CircleNew Kensington, PA 15068Phone: 724-334-5051Fax: 724-334-5723Email: help@MyBacharac
Headquarters:621 Hunt Valley Circle, New Kensington, PA 15068Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 800-736-4666Website: www.MyBacharach.co
Instruction 0024-93951Fyrite Pro1.0 INTRODUCTION1.1 The Fyrite ProThe Fyrite Pro series of instruments are hand-held an a lyz ers that are designed f
Instruction 0024-93952Fyrite Pro1.2 Operational OverviewPressing the I/O button turns the analyzer ON. Note that there is a warm-up period of either 1
Instruction 0024-93953Fyrite Pro2.0 TECHNICAL CHARACTERISTICSThe Analyzer Directly Measures and Displays:• Ambient Temperature .......