screwdriver adjustable sensor heat con-
trol is located on the bottom of the unit.
The probe nozzle consists of a trans-
parent tip, airflow ball, filter, and neon
leak-signal lamp, connected to the con-
trol chassis by a length of flexible tubing.
The calibrated reference leak is a
removal bottle containing halogen gas
R11, and is calibrated to provide a leak
equivalent to approximately 0.5 ounce
per year of R134a. As an accessory, a
maintenance kit is provided that contains
extra filters and airflow balls.
Application
The H-10G is intended principally for
use as a serviceman’s tool, although it
also can be used for production line leak
testing. It was developed in response
to an industry that is in the process of
converting to more environmentally safe
refrigerants worldwide. Ozone depleting
chlorine is being reduced or eliminated in
most refrigerants. To adequately leak test
refrigerants like R123 and fluorine based
R134a, a higher detector sensitivity is
required. The H-10G has the capabil-
ity to detect small leaks for all current
chlorine based refrigerants as well as the
new fluorine based R134a or new blends
under development. When using the
H-10G you can be confident it has the
sensitivity to meet your service needs of
today and the capability of meeting your
needs in the years to come.
Please note that heavy gas contamina-
tion in the testing area may cause erratic
operation of the H-10G. This can occur
when the leak in the system is very
large and there is little or no ventilation
in the testing area. Contamination of an
Page view 2