Bacharach Stinger 2000 User Manual

Browse online or download User Manual for Split-system air conditioners Bacharach Stinger 2000. Bacharach Stinger 2000 User manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User Manual

High Performance Oilless Commercial Refrigerant Recovery Unit User Manual 2079-1130 Rev. 6 – M

Page 2 - Introduction

10 Standard Recovery Hose Connections IMPORTANT NOTES FOR LIQUID RECOVERY Do not pump virgin refrigerant with the STINGER. Unlike recovered refrig

Page 3 - STINGER Specifications

11 Liquid Push-Pull Recovery Operations Attention: Before attempting liquid push-pull recovery operations, please review this page. A scale or li

Page 4 - Table of Contents

12 Liquid Push-Pull Operations Continued 4. Open both the vapor and liquid valves on the DOT recovery tank. 5. Turn ON the STINGER. The compressor

Page 5 - General Safety

13 Liquid-Pull Recovery / Charging Method Do not pump virgin refrigerant with the STINGER. Unlike recovered refrigerant, virgin refrigerant does not

Page 6 - Operational Safety

14 R-410A Recovery – Special Notes R-410A is a replacement refrigerant for R-22. Its physical properties, however, are much different than R-22. R-4

Page 7 - Description of Features

15 Purging the STINGER The STINGER is equipped with a pump-down purge valve that allows the technician to pump down or evacuate the STINGER before p

Page 8

16 DOT Recovery Cylinder Safety WARNING! This unit is capable of over-pressurizing a DOT recovery cylinder. Ensure that you are using the proper

Page 9

17 Recovery Tips • Use the shortest hoses possible. Long hoses increase the recovery time. Remove all restrictions in the hoses. Hoses with ball va

Page 10

18 Troubleshooting PROBLEM CAUSE ACTION Unit will not start – Fan does not run; compressor does not start Power Cord not attached No voltage at rec

Page 11

19 Schematic Diagrams

Page 12

2 Introduction Congratulations on your purchase of the STINGER high performance oilless recovery unit. Bacharach has worked hard to make the STINGER

Page 13

20 STINGER Parts List See STINGER Exploded View on Page 21. Item No. Part Number Description Qty 1 2045-0620 Compressor (110/120 VAC) 1 1 2045-072

Page 14

21 STINGER Exploded View

Page 15 - Purging the STINGER

22 Compressor Parts List See Compressor Exploded View on Page 23. Part No. Item Description Qty 2081-0410 1 Motor Shaft Head Bearing 1 2081-

Page 16 - DOT Recovery Cylinder Safety

23 Compressor Exploded View

Page 17 - Recovery Tips

24 Warranty / Repair Procedures Bacharach warrants this product for 1 year from the date of purchase indicated on the original sales receipt. The w

Page 18 - Troubleshooting

3 STINGER Specifications STINGER Compatible Refrigerants R-12, R-22, R-114, R-134a, R-401A, R-401B, R-401C, R-402A, R-402B, R-404A, R-406A, R-407A

Page 19 - Schematic Diagrams

4 Table of Contents Introduction ... 2 STINGER Specificati

Page 20 - STINGER Parts List

5 General Safety Know your equipment Read and understand the User Manual and labels affixed to the unit. Learn the application and limitations as we

Page 21 - STINGER Exploded View

6 Operational Safety WARNING: Inhalation of high concentrations of refrigerant vapors is harmful and may cause heart irregularities, unconsciousne

Page 22 - Compressor Parts List

7 Description of Features 1. Inlet Gauge Displays the inlet/suction pressure of the system being evacuated. 2. Purge Valve This valve determin

Page 23 - Compressor Exploded View

8 Description of Features Continued 10. Power Cord (Note: 220 VAC units have a male IEC 60320 type plug that requires the use of a c

Page 24 - Warranty / Repair Procedures

9 Vapor/Liquid Recovery Operations Perform the following steps when recovering refrigerant that is either in vapor or liquid form. Note: Refer to

Comments to this Manuals

No comments