Specifications
Product Sensitivity (moving probe)
(Movement not to exceed 2 in/sec, not
greater than 0.25 inches from leak.)
Switch
Position LG MD SM
R134a 5.0 1.0 0.5
R12 3.0 0.5 0.1
Product Sensitivity (stationary probe)
(Probe directly on leak source, no
movement.)
Switch
Position LG MD SM
R134a 5.0 0.5 0.1
R12 3.0 0.1 .05
Power Supply ±10% (100, 120, 220,
240 volts) 50/60 Hz
20 watts, in accor-
dance with rating plate
Response Time Approx. 1 second
Reference Leak Approx. 0.5 oz/yr R134a.
Approx. 6 months life,
refillable with R11.
Warm-up Time Approx. 2 minutes
Temperature Operating 0°C to 45°C
(32°F to 113°F)
Storage 60°C (140°F) max.
Dimensions 8.7 x 5.5 x 1.4 inches
(22 x 14 x 7.5 cm)
Weight 3.2 pounds
(1.4kg)