Bacharach Refrigerant Recovery System 3600 Specifications Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
2
FLUOROMIZER
S
PECIFICATIONS
Model 3600-R410A Portable Commercial Oilless Recovery System
Refrigerants R12, R-22, R-134a, R-500, R-502, R-410AHP/MP Blends
Power Source 120V AC 60 Hz
Wattage/Amperes 800 W / 8.0 A max
Compressor ½ HP High Performance Oilless
High Pressure Shutoff 550 psi
Dimensions Height 12.0"
Width 13"
Depth 7.5"
Weight 35 Lbs.
Refrigerant Recovery Rates
Certified per ARI 740-95 & 740-98
Refrigerant Liquid Rate Liquid Push-Pull Rate Vapor Rate
R-22
4.96 lb/min
2.25 kg/min
13.01 lb/min
5.90 kg/min
0.37 lb/min
0.17 kg/min
R-134A
3.86 lb/min
1.75 kg/min
11.84 lb/min
5.37 kg/min
0.29 lb/min
0.13 kg/min
R-410A
3.31 lb/min
1.50 kg/min
15.70 lb/min
7.12 kg/min
0.42 lb/min
0.19 kg/min
TABLE OF CONTENTS
Fluoromizer Specifications & Features ............................................................... 2
Introduction ......................................................................................................... 3
General Safety Instructions ................................................................................ 4
Operational Safety ............................................................................................. 5
Description of Features ...................................................................................... 6-7
Helpful Hints for Recovering R-410A .................................................................. 7
Vapor Recovery Procedures .............................................................................. 8
Vapor Recovery Hose Connections (Figures 1&2) ............................................. 9
Liquid Recovery General Information. ................................................................ 10
Liquid Recovery Procedures .............................................................................. 11
Liquid Push-Pull Hose Connections - (Figures 3&4) .......................................... 12
Pump Down Operations ..................................................................................... 13
DOT Recover Cylinder Safety ............................................................................ 14
Troubleshooting Guide ....................................................................................... 15
Electrical Schematic ........................................................................................... 16