Indoor Environment Quality Monitor Instruction 1509-9001 Operation Manual Rev. 1 - July 2011 Product Leadership • Tr
IEQ Chek Operation Manual 2 1509-9001 Rev 1 1.2. IEQ Chek™ Shipping Checklist This checklist ensures that you have received everything require
IEQ Chek Operation Manual 1509-9001 Rev 1 3 2 SPECIFICATIONS 2.1. General Categories/Subcategories Descriptions Enclosure Dimensions L x W
IEQ Chek Operation Manual 4 1509-9001 Rev 1 Figure 2-1. IEQ Chek™ Dimensions 3.06 7.75 3.87″ (9.8 cm)
IEQ Chek Operation Manual 1509-9001 Rev 1 5 2.2. IQ Chek™ DataLogging Software (Optional) Minimum system requirements to operate the optional
IEQ Chek Operation Manual 6 1509-9001 Rev 1 3. KEY COMPONENTS 3.1. Key Components: Front and Bottom Views
IEQ Chek Operation Manual 1509-9001 Rev 1 7 3.2. Key Components: Left Side View Figure 3-2. IEQ Chek™ Key Com
IEQ Chek Operation Manual 8 1509-9001 Rev 1 3.3. Key Components: Top and Back Views Figure 3-3. IEQ Chek™ Key
IEQ Chek Operation Manual 1509-9001 Rev 1 9 4. INSTRUMENT OPERATION 4.1. General The IEQ Chek™ has an extensive menu system allowing the use
IEQ Chek Operation Manual 10 1509-9001 Rev 1 4.2. Switching the Instrument On/Off NOTE: When using push-buttons on front of instrument enclos
IEQ Chek Operation Manual 1509-9001 Rev 1 11 4.4. Main Menu Functional Overview Pressing the MENU button after the main sensor array is displa
IEQ Chek Operation Manual ii 1509-9001 Rev 1
IEQ Chek Operation Manual 12 1509-9001 Rev 1 5. MENU FUNCTION DETAILS 5.1. Calibrate Menu Pressing the MENU button when CALIBRATE is selecte
IEQ Chek Operation Manual 1509-9001 Rev 1 13 5.2. Settings Menu This menu item provides the user with the ability to configure much of the ins
IEQ Chek Operation Manual 14 1509-9001 Rev 1 BATTERY: This menu item provides the user with two different battery options that can be selected.
IEQ Chek Operation Manual 1509-9001 Rev 1 15 PUMP: This menu item allows the user to select REG FLOW (regular flow) or HIGH FLOW for the pump.
IEQ Chek Operation Manual 16 1509-9001 Rev 1 After the sampling rate has been selected, the logger START method must be selected from one of the
IEQ Chek Operation Manual 1509-9001 Rev 1 17 NONE SETUP KOREA MOM HOME CONF RM5 <EMPTY> MEM CARD: This menu item provides the user with i
IEQ Chek Operation Manual 18 1509-9001 Rev 1 NEXT: Select next after you have highlighted only the sensors you want to have alarm set points f
IEQ Chek Operation Manual 1509-9001 Rev 1 19 To access this information, scroll down to the desired sensor choice and using the ARROW DOWN but
IEQ Chek Operation Manual 20 1509-9001 Rev 1 6.3. Calibration Process: Zero Press the MENU button on the instrument to enter the main menu. U
IEQ Chek Operation Manual 1509-9001 Rev 1 21 Step 3-Point Span Procedure 3. Enter the security code correctly and the LCD indicates CAL. Using
IEQ Chek Operation Manual 1509-9001 Rev 1 iii IMPORTANT NOTE READ AND UNDERSTAND THIS MANUAL PRIOR TO USING THIS INSTRUMENT. CAREFULLY READ
IEQ Chek Operation Manual 22 1509-9001 Rev 1 Step 1-Point Span Procedure 1. First, complete the zero calibration procedure as indicated on pag
IEQ Chek Operation Manual 1509-9001 Rev 1 23 All IEQ Chek gas sensors are plug-and-play smart sensors. They can be added or changed at any time
IEQ Chek Operation Manual 24 1509-9001 Rev 1 Step Procedure to Add/Change a Sensor 4. If another sensor is to be installed in its place, ensure
IEQ Chek Operation Manual 1509-9001 Rev 1 25 Slot Location Restrictions 1 O2 (if used) MUST use this slot. Otherwise, it may contain a toxic
IEQ Chek Operation Manual 26 1509-9001 Rev 1 10. ACCESSORIES 10.1. Hard Shell, Foam-Lined Carrying/Transport Case The part number for the tra
IEQ Chek Operation Manual 1509-9001 Rev 1 27 11. DUAL PROBE VERSION 11.1. Applications Overview A dual-probe version of the IEQ Chek is av
IEQ Chek Operation Manual 28 1509-9001 Rev 1 sensors at the tip of the temperature/RH probe, the relative humidity (RH) and temperature level
IEQ Chek Operation Manual 1509-9001 Rev 1 29 11.3. Instrument Kits for Dual-Probe Applications Specific versions of the IEQ Chek are availab
IEQ Chek Operation Manual 30 1509-9001 Rev 1 11.4. Application Setup and Configuration Operation of the IEQ Chek dual-probe versions require
IEQ Chek Operation Manual 1509-9001 Rev 1 31 12. MENU ARCHITECTURE Below is a high-level architecture diagram of the IEQ Chek menu system.
IEQ Chek Operation Manual iv 1509-9001 Rev 1 SERVICE POLICY BACHARACH, INC. MAINTAINS AN INSTRUMENT SERVICE FACILITY AT THE FACTORY. SOME BACHA
IEQ Chek Operation Manual 32 1509-9001 Rev 1 World Headquarters 621 Hunt Valley Circle, New Kensington, Pennsylvan
IEQ Chek Operation Manual 1509-9001 Rev 1 v DISCLAIMER UNDER NO CIRCUMSTANCES WILL BACHARACH, INC. BE LIABLE FOR ANY CLAIMS, LOSSES, OR DAMAGES
IEQ Chek Operation Manual vi 1509-9001 Rev 1 TABLE OF CONTENTS 1. OVERVIEW ...
IEQ Chek Operation Manual 1509-9001 Rev 1 vii 11. DUAL PROBE VERSION ...
IEQ Chek Operation Manual viii 1509-9001 Rev 1
IEQ Chek Operation Manual 1509-9001 Rev 0 1 1. OVERVIEW 1.1. General Description Thank you for purchasing the IEQ Chek™ indoor environmental